Aurora inverters were manufactured in Italy and imported to Australia by ABB. They came with a 5-year warranty and have been installed from 2010 to present.
If your faulty Aurora inverter is still under warranty, Solargain can help you file an insurance claim. You will need to provide a photo of the screen displaying the fault as well as a photo of the sticker located on the side of the unit, which displays the serial, WK and part numbers. Please note the claim can take up to 3 weeks to process. If your inverter is out of warranty, we can contact the manufacturer to see if they will still honour it.
Some faults require a site attendance, which will be covered if you are a Solargain customer. If not, you will need to pay for a health check so we can properly assess the safety of the installation.
Fault Code | Description | Remedy | |
W001 | Sun Low | This error indicates a low DC, which is normal on cloudy days, in the early morning and in the late afternoon. Outside of these situations, it might suggest a panel issue. You will need to book a health check so our electricians can test your panels. | |
E001 | Input OC | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter will need replacing. | |
W002 | Input UV | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter will need replacing. | |
E002 | INPUT OV | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter will need replacing. | |
E003 | Int.Error | The inverter will need replacing. | |
E004 | BULK OV | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter will need replacing. | |
E005 | Int.Error | As this is a communication error, a reset of a system might fix it. If it doesn't, the inverter will need replacing. | |
E006 | OUT OC | The inverter will need replacing. | |
E007 | Int.Error | The inverter will need replacing. | |
E008 | Int.Error | The inverter will need replacing. | |
E009 | Int.Error | The inverter will need replacing. | |
W003 | Grid Fail | Check that the solar supply main switch is on. If it is, the inverter will need replacing. | |
E010 | Int.Error | The inverter will need replacing. | |
E011 | Int.Error | The inverter will need replacing. | |
E012 | dc/dc fail | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter will need replacing. | |
E013 | wrong mode | Please book a health check so our technicians can check the settings on your inverter. If they are all correct, the inverter will need replacing. | |
E014 | over temp | If this fault is intermittent, it won't affect production. If it is constant, the inverter may need replacing. | |
E015 | cap Fault | The inverter will need replacing. | |
E016 | inv fail | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter needs replacing. | |
E017 | Int.Error | ||
E018 | ground D | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter needs replacing. | |
E019 | Int.Error | The inverter will need replacing. | |
E020 | Int.Error | The inverter will need replacing. | |
E021 | Int.Error | The inverter will need replacing. | |
E022 | Int.Error | ||
E023 | Int.Error | The inverter will need replacing. | |
W004 | grid OV | This fault indicates a grid issue and should be intermittent. If it is constant, the inverter may need replacing. | |
W005 | Grid UV | This fault indicates a grid issue and should be intermittent. If it is constant, the inverter may need replacing. | |
W006 | GRID OF | This fault indicates a grid issue and should be intermittent. If it is constant, the inverter may need replacing. | |
W007 | GRID UF | This fault indicates a grid issue and should be intermittent. If it is constant, the inverter may need replacing. | |
W008 | Z GRID HI | ||
E024 | Int.Error | The inverter will need replacing. | |
E025 | Low insulation resistance | Please book a health check so our electricians can test your panels. If they are not faulty, the inverter needs replacing. | |
E026 | Int.Error | The inverter will need replacing. | |
E027 | Int.Error | The inverter will need replacing. | |
E028 | Int.Error | The inverter will need replacing. | |
E030 | Int.Error | The inverter will need replacing. | |
E031 | Int.Error | The inverter will need replacing. | |
E032 | Int.Error | The inverter will need replacing. | |
W010 | fan fail | The inverter will need replacing. | |
E033 | Int.Error | The inverter will need replacing. |